UPS Aviation Technologies GX-55Precio GX-55:Precio GX-55R: Precio GX-55 OH: Consultar precio de instalación |
|
| FEATURES | |
|
| SPECIFICATIONS | |||
| Input Voltage: | 10 VDC to 40 VDC, reverse polarity protected | Input Power: | 7 watts typical |
| Input Current: | 500 mA typical, 750 mA max at
13.75 VDC 250 mA typical, 375 mA max at 27.5 VDC |
Height: | 2.00 inches |
| Width: | 6.25 inches | Depth: | 11.452 inches |
| Weight: | 2.6 lb | Operating Temperature: | -20C to +55C |
| Maximum Altitude: | 35,000 ft | Number of Channels: | 8 |
| Frequency: | 1575.42 MHz L1, C/A code | Sensitivity (acquisition): | -135dBm |
| Sensitivity (drop lock): | -142dBm | Dynamic Range: | >20 dB |
| Lat/Lon position accuracy: | 15 meters RMS typical 25 meters, SEP, without SA 100 meters 2DRMS with SA |
Velocity: | 1000 knots maximum |
| Acceleration: | 4G maximum | Time to First Fix: | 25 seconds typical |
| Reacquisition: | 2.5 seconds typical | Position Update Interval: | 1 second typical |
| Datum: | WGS-84 | CDI L/R Variation: | +/- 150 mv full scale, will drive up to 200 ohm load |